Características Físicas (Generales)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|---|---|---|---|
13 | 7x21 | BC - Bare Copper | 0.085 in | 1 |
Conductor Count: | 1 |
Insulation
Material | Nominal Diameter |
---|---|
PE - Polyethylene | 0.285 in |
Outer Shield Material
Type | Material | Coverage [%] |
---|---|---|
Braid | BC - Bare Copper | 95 % |
Outer Jacket Material
Material | Nominal Diameter |
---|---|
PVC - Polyvinyl Chloride | 0.403 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
---|---|---|
1.9 Ohm/1000ft | 1.2 Ohm/1000ft | 1.2 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
28.5 pF/ft |
Inductance
Nominal Inductance |
---|
0.079 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
50 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|---|
1 MHz | 0.2 dB/100ft |
10 MHz | 0.6 dB/100ft |
50 MHz | 1.3 dB/100ft |
100 MHz | 1.9 dB/100ft |
200 MHz | 2.8 dB/100ft |
400 MHz | 4.2 dB/100ft |
700 MHz | 5.9 dB/100ft |
900 MHz | 6.9 dB/100ft |
1000 MHz | 7.4 dB/100ft |
4000 MHz | 23.2 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|---|
1.54 ns/ft | 66 % |
Power Rating
Frequency [MHz] | Max. Power Rating [W] | Nominal Power Rating [W] |
---|---|---|
50 MHz | 1,200 W | 1,200 W |
100 MHz | 800 W | 800 W |
400 MHz | 320 W | 320 W |
1,000 MHz | 180 W | 180 W |
Voltage
Non-UL Voltage Rating |
---|
3700 V RMS |
Temperature Range
UL Temp Rating: | 75°C |
Operating Temp Range: | -40°C To +75°C |
Mechanical Characteristics
Bulk Cable Weight: | 102 lbs/1000ft |
Max Recommended Pulling Tension: | 190 lbs |
Min Bend Radius/Minor Axis: | 4.25 in |
Standards
NEC/(UL) Specification: | CMH |
CEC/C(UL) Specification: | CMH |
CPR Euroclass: | Eca |
RG Type: | 8/U Type |
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2003/96/EC (BFR): | Yes |
EU Directive 2011/65/EU (ROHS II): | Yes |
EU Directive 2012/19/EU (WEEE): | Yes |
EU Directive Compliance: | EU Directive 2003/11/EC (BFR) |
EU CE Mark: | No |
EU RoHS Compliance Date (yyyy-mm-dd): | 2004-01-01 |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Suitability
Suitability - Aerial: | Yes - Black only, when supported by messenger wire |
Suitability - Burial: | No |
Suitability - Hazardous Locations: | No |
Suitability - Indoor: | Yes |
Suitability - Outdoor: | Yes - Black only |
Flammability, LS0H, Toxicity Testing
ISO/IEC Flammability: | IEC 60332-1-2 |
Plenum/Non-Plenum
Plenum (Y/N): | No |
Part Number
Variants
Item # | Color | UPC | Length | Footnote |
---|---|---|---|---|
8237 010100 | Black | 612825196693 | 100 ft | C |
8237 0101000 | Black | 612825196709 | 1,000 ft | C |
8237 010500 | Black | 612825355625 | 500 ft | C |
Footnote: | C - CRATE REEL PUT-UP. |
History
Update and Revision: | Revision Number: 0.274 Revision Date: 08-22-2019 |